1/1

flame photometer

Quick Details
Product Code:
1002
OEM:
Available
Sample:
Refuse
Payment:
PayPal,VISA,MasterCard,Western Union,L/C,T/T,D/P,D/A,Other
Place of Origin:
China
Shipping:
Support Express · Sea freight · Land freight · Air freight
Supply Ability:
1000 unit per month
Quick Details
  • Display
    7 inches high resolution TFT colored capacitive touch screen
  • Display Results
    Concentration Value/Energy
  • Reading range
    0.000~999.9/0~65535
  • Response time
    ≤8S
  • Minimum spray volume
    ≤6ml/min
  • Output
    USB port
  • Wavelength Range
    190-1100nm
  • Focal Length
    0.3nm
  • Reproducibility
    3%
  • flame photometer
    K Na Li Ca Ba
OK
Shipping fee
Shipping fee
Inquiry Basket
Contact Supplier

Laboratory Digital FP6410 broken line method, straight line method espectometro K Na Li Ca Ba flame photometer instrument

Application
The flame photometer has the characteristics of high sensitivity, strong selectivity, less samples required, and fast analysisspeed, and has been widely used in the following fields:
1. Testing of building materials such as cement, glass, ceramics, andrefractory materials.
2. Fertilizer and soil testing.
3. Testing of mining, petroleum, metallurgy and chemical products.
4. Food testing such as pharmaceuticals and beverages.
5. Municipal solid waste testing.
6. Tests for various experiments in scientific research, health, teaching and other fields.

Feature:
1. 7 inch touch screen LCD
2. Direct concentration read-out
3. Automatic Calculation of correlation coefficient
4. Pre-selection of flame sizes
5. Flameout protection device
6. Measuring range changing
7. LPG burning gas
8. Air compressor including



Model
FP6450
FP6440
FP6432
FP6431
FP6430
FP6410
Display
7 inches high resolution TFT colored capacitive touch screen
Display Results
Concentration Value/Energy
Reading range
0.000~999.9/0~65535
 
5
4
3
3
3
2
 
 
Detection Limit mmol/L
K
≤0.004
≤0.004
≤0.004
≤0.004
≤0.004
≤0.004
Na
≤0.008
≤0.008
≤0.008
≤0.008
≤0.008
≤0.008
Li
≤0.015
≤0.015
——
——
≤0.015
——
Ca
≤0.050
≤0.050
——
≤0.050
——
——
Ba
≤0.044
——
≤0.044
——
——
——
 
 
 
Linear Error mmol/L
K
≤0.005
≤0.005
≤0.005
≤0.005
≤0.005
≤0.005
Na
≤0.003
≤0.003
≤0.003
≤0.003
≤0.003
≤0.003
Li
≤0.021
≤0.021
——
——
≤0.021
——
Ca
≤0.075
≤0.075
——
≤0.075
——
——
Ba
≤0.066
——
≤0.066
——
——
——
Response time
≤8S
Minimum spray volume
≤6ml/min
 
Stability
With continuous sample injection of standard solution, the relative big change of instrument reading within 15s is ≤ 3%. Measure
once per minute for a total of 6 times, with a big change in instrument readings is ≤ 15%.
Repeatability
Repeat 7 consecutive measurements for the same standard solution ≤ 3%
Output
USB port
Automatic calculation of linear regression
Yes
Question & Answer