1/2

UV Visible Spectrophotometer

Quick Details
OEM:
Available
Sample:
Refuse
Port:
Nan shaPort,HUANGPU,YANTIAN,SHEKOU
Payment:
PayPal,VISA,Western Union,T/T,Other
Place of Origin:
China
Shipping:
Support Express · Sea freight · Land freight · Air freight
Supply Ability:
100 unit per day
Quick Details
  • Certification
    CE FCC
  • Optical Systen
    Single Beam
  • Light Source
    Tungsten lamp& Deuterium lamp
  • Spectral Bandwidth
    2.0nm
  • Wavelength Accuracy
    ±0.5nm
  • Wavelength Repeatability
    ≤0.3nm
  • Sample Compartment
    4-position,10mm pathlength cuvette
  • Display
    LCD
  • Output
    USB Port&Parallel Port (Printer)
  • Power
    110/220VAC, 50/60Hz,120W
  • Dimension (L×W×H)
    490×360×210mm
OK
Shipping fee
Shipping fee
Inquiry Basket
Contact Supplier

SP-UV1100

Key Features

•   User Friendly Operation and Information Rich LCD Display: 

     The large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.

•   On-Board Data Storage: 

    The System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.

•   Data can be restored after a sudden power failure.

•   Auto setting wavelength: 

    To set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.

•   Automatic Switching: 

    Tungsten& Deuterium lamps switching is automatic. Selectable from a wavelength range of  190 to 1100nm.

•   PC control through application software: The spectrophotometer is fully equipped and capable of executing all functions in stand-alone mode.

    The optional application software 'Wave Professional' provides computer control for the spectrophotometer(through the built-in USB port),

    apart from other functions such as spectrum scan, Time scan(kinetics), multiwavelength scanning & Nucleic Acid /Protein measurement. (SP-V1100/SP-UV1100)

•   Large sample compartment: 

    To accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.

 

SP-V1100

Key Features

•   User Friendly Operation and Information Rich LCD Display: 

    The large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.

•   On-Board Data Storage: 

    The System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.

•   Data can be restored after a sudden power failure.

•   Auto setting wavelength: 

    To set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.

•   Large sample compartment:

    To accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.

 

 SP-UV1000

Key Features

•   User Friendly Operation and Information Rich LCD Display: 

    The large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.

•   On-Board Data Storage: The System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.

•   Data can be restored after a sudden power failure.

•   Auto setting wavelength: To set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.

•   Automatic Switching: Tungsten& Deuterium lamps switching is automatic. Selectable from a wavelength range of  190 to 1100nm.

•   Large sample compartment: To accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.

 

 SP-V1000

Key Features

•   User Friendly Operation and Information Rich LCD Display:

    The large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.

•   On-Board Data Storage: 

    The System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.

•   Data can be restored after a sudden power failure.

•   Auto setting wavelength: 

    To set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.

•   PC control through application software: 

    The spectrophotometer is fully equipped and capable of executing all functions in stand-alone mode. The optional application software

   'Wave Professional' provides computer control for the spectrophotometer(through the built-in USB port), apart from other functions such

    as spectrum scan, Time scan(kinetics), multiwavelength scanning & Nucleic Acid /Protein measurement. (SP-V1100/SP-UV1100)

•   Large sample compartment: To accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.

Specifications SP-UV1100 SP-V1100 SP-UV1000 SP-V1000
Optical Systen Single Beam Single Beam Single Beam Single Beam
Light Source
Tungsten lamp&
Deuterium lamp
Tungsten lamp   Tungsten lamp&
  Deuterium lamp
Tungsten lamp 
Spectral Bandwidth 2.0nm 2.0nm 4.0nm 4.0nm
Wavelength Range  190-1100nm 320-1100nm 200-1000nm 325-1000nm
Wavelength Accuracy ±0.5nm ±0.5nm ±2nm ±2nm
Wavelength Repeatability ≤0.3nm ≤0.3nm  ≤1nm ≤1nm
Photometric Range
 -0.3-3.0A,
0-200%T
-0.3-3.0A, 0-200%T
-0.3-3.0A,
0-200%T
-0.3-3.0A,
0-200%T
Photometric Accuracy ±0.002A@0.5A,
 ±0.004A@1.0A,
±0.3%T@100%T
±0.002A@0.5A,
±0.004A@1.0A,
±0.3%T@100%T
±0.003A@0.5A,
±0.006A@1.0A
   ±0.5%T@100%T
±0.003A@0.5A,
±0.006A@1.0A,±0.5%T@100%T
 Photometric Repeatability ≤0.001A@0.5A,
≤0.002A@1.0A,
≤0.15%T@100%T
≤0.001A@0.5A,
≤0.002A@1.0A,
≤0.15%T@100%T
≤0.0015A@0.5A,
≤0.003A@1.0A,     
≤0.25%T@100%T
≤0.0015A@0.5A,
≤0.003A@1.0A,
≤0.25%T@100%T
Stability ≤0.002A/h @500nm
(after preheat 2 hours)
≤0.002A/h @500nm
(after preheat 2 hours)
≤0.002A/h @500nm
(after preheat 2 hours)
≤0.002A/h @500nm
(after preheat 2 hours)
Stray Light ≤0.05%T@220&360nm  ≤0.05%T@360nm  ≤0.2%T@220&360nm ≤0.2%T@360nm
Sample Compartment 4-position,10mm
pathlength cuvette
 4-position,10mm
pathlength cuvette
4-position,10mm
pathlength cuvette
4-position,10mm
pathlength cuvette
Display  LCD LCD LCD LCD
Output USB Port&Parallel Port (Printer) USB Port&Parallel Port (Printer) USB Port&Parallel Port (Printer) USB Port&Parallel Port (Printer)
Power 110/220VAC,50/60Hz,120W 110/220VAC, 50/60Hz,80W  110/220VAC,50/60Hz,120W 110/220VAC, 50/60Hz,80W
Dimension (L×W×H) 490×360×210mm 490×360×210mm 490×360×210mm 490×360×210mm
Weight 14kg  12kg 14kg 12kg
Question & Answer