Atomic Absorption Spectrophotometer

Quick Details
OEM:
Available
Sample:
Available
Payment:
PayPal,VISA,MasterCard,Western Union,L/C,T/T,D/P,D/A,Other
Place of Origin:
China
Supply Ability:
100 unit per week
Quick Details
  • Optical System
    Single Beam/ Double Beam
  • Monochromator
    Czerny-Turner type, focal lengths at 350mm
  • Grating
    Holographic diffraction with 1800 lines/mm
  • Wavelength Range
    190-900 nm
  • Slits
    Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
OK
Shipping fee
Shipping fee
Inquiry Basket
Contact Supplier
Atomic Absorption Spectrophotometer  
 
The Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with optional graphite furnace,
auto sampler and hydride generator. Unique optical mechanical design, safe and convenient flame system, optional background
correction technologies, as well as convenient functions provided by the workstation, suit your pursuit of automatic and precise test results.
 
Features:          
1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
4. Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
5. Original lamp position eight lamp holder 360 degree rotation design.
6. Novel atomizer and intelligent elevator.
7. Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.
 
Specification:
 
Models AA 7804 AA 7808 AA 7818 AA 7828
Optical System Single Beam Single Beam Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Holographic diffraction with 1800 lines/mm
Wavelength Range 190-900 nm
Slits Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Repeatability ±0.1nm ±0.1 nm ±0.05 nm ±0.05 nm
Wavelength Accuracy ±0.3 nm ±0.2 nm ±0.15 nm ±0.15 nm
Lamp Automated 4-lamp turret Automated 8-lamp turret Automated 8-lamp turret Automated 8-lamp turret
Reading Mode T, A, C
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ≤0.004A/30 min ≤0.003A/30 min ≤0.002A/30 min ≤0.002A/30 min
Dynamic Baseline Drift (Cu) ≤0.006A/15 min ≤0.005A/15 min ≤0.004A/15 min ≤0.004A/15 min
Background Correction Deuterium (D2) Background Correction Deuterium (D2) Background Correction and Self-absorption Background Correction
Flame Characteristic Concentration ≤0.04ug/ml ≤0.035ug/ml ≤0.02ug/ml ≤0.02ug/ml
Detection Limit (Cu) ≤0.008ug/ml ≤0.006ug/ml ≤0.004ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤1% RSD≤0.6% RSD≤0.5% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Ignition Method PC control